Evaluating the new KIC Navigator Option to Select Optimal Oven Recipe for Reduced Power Consumption, for Sn-Pb and Pb-Free Reflow Soldering
E-mail
Center for Electronics Manufacturing and Assembly
Rochester Institute of Technology, Rochester, New York 14623

http://smt.rit.edu

Goal

To study the efficiency of new Navigator Power option in KIC 2000, to select an optimal oven recipe for reduced power consumption, for Sn-Pb and Pb-Free reflow soldering.

Objective

  • To use the new KIC Navigator option to generate and select oven recipes for reduced power consumption
  • To measure the reduction in energy consumption by comparing the following:
    • The energy consumed for the existing in-spec oven recipe, for a production run and
    • The equivalent energy consumed after changing the oven recipe to the settings suggested by the new KIC Navigator option

KIC 2000 - Navigator

The new KIC 2000 Navigator Power software has the following three profile optimization settings:

  • Minimize PWI:
    This option will search for different set point temperatures and conveyor speeds which will reduce the PWI (Process Window Index)
  • Maximize Conveyor Speed:
    This option will search for the set point temperatures that will maximize the conveyor speed
  • Minimize Energy Consumption:
    This option will search for an in-spec profile with lower temperature settings and conveyor speed that will minimize power consumption and maintain the PWI below a specified maximum

KIC 2000 Terminology

  • Process Window Index (PWI)
    The PWI is a measure of how well a profile performs relative to critical process limits.  It is specified as an absolute value in %.  The lower the PWI, the closer the profile is to the specification targets.  The center of the process window is zero and the extreme ends of the process window are ±99%.  A PWI of 100% or more will indicate that the profile is not in specifications.
  • In-spec Profile
    An in-spec profile for a product refers to any reflow profile with PWI <100%.  In Fig.1, the area enclosed by the outer most circles (100%) forms the in-spec profile area.  Any region outside the largest circle is considered out-of-spec.

    [Process Windows Index (PWI)]
    Figure 1:  Process Window Index (PWI) and In-spec Profile

    The individual data points for each parameter are represented by the solid beads.  The bead farthest from the center (max PWI) is the worst-case scenario in PWI and is considered the PWI of the profile.

Experimental Study

  • Three different companies were selected for this project.
    • Company A:  Surmotech CMS is a full-service contract manufacturer specializing in high-reliability medical, industrial and military applications.  Located in Victor, NY, Surmotech is an ISO 9001:2000 registered company that focuses on providing complete turnkey solutions that include design, prototyping, engineering, materials management, testing and field service.
    • Company B: Marquardt is a global manufacturer of electromechanical and electronic components, supplying the hand tool and automotive industries.
    • Company C: SenDEC is organized into two main business units: the Contract Electronics Manufacturing (CEM) Group and the Products Group.  SenDEC's CEM Group provides electronics manufacturing services (EMS) including design, prototype, PCB assembly, electromechanical assembly, test engineering, rework, material management and turnkey box build services.  The SenDEC Products Group manufactures its own family of digital monitoring, display and control devices for numerous markets across the globe.
  • The different assemblies considered for the experimental runs in the three companies is shown below:

     

    Sn-Pb Pb-Free
    Company A X
    Company B X
    Company C X X (2)
    *The number in the parenthesis indicates number of products run

     

  • Power consumption measurement was carried out by installing a meter on the oven at each site, to record the amount of power being consumed for the production runs, for each profile.

Experimental Procedure

  • At each site, the product that is to be used for the production runs is identified.
  • Reflow profile set points and paste details for that product are taken from the customer.
  • The product is run using the existing profile set points to check if the reflow profile is in-spec with respect to the paste manufacturer specifications or the company's approved specifications.
  • If the profile is not in-spec, the customer is asked to bring the process in-spec, using their current method.
  • Once the profile is in-spec, the production run is executed for at least a 3-hour period.
  • Following the 3-hour period, the new KIC Navigator option is used to identify a recipe (oven setpoints) for reduced power consumption.
  • The new recipe is loaded in the oven.  After the oven stabilizes, a test board is run for approval by the quality control department within the company.
  • Subsequent to the approval from the quality department, the production run is executed for the next 3-hour period.
  • The power consumption is recorded continuously for both the profiles and then analyzed for difference and statistical significance of the difference, using a t-Test.

Data collection

Company A:

  • Oven name: Speedline Technologies Electrovert Bravo 8105
  • No of Zones: 8
  • No of products run: 1 Sn-Pb
    Sn-Pb Product Zone #1 Zone #2 Zone #3 Zone #4 Zone #5 Zone #6 Zone #7 Zone #8 Conveyor Speed PWI Temperature set point difference
    Existing set points 120 140 170 170 180 205 230 245 30 in/min N/A 13C
    KIC set points 112 130 160 182 182 194 245 242 25 in/min 22%

Company B:

  • Oven name: Rehm V8 Nitro 32 B
  • No of Zones: 7
  • No of products run: 1 Sn-Pb
    Sn-Pb Product Zone #1 Zone #2 Zone #3 Zone #4 Zone #5 Zone #6 Zone #7 Conveyor Speed PWI Temperature set point difference
    Existing set points 120 140 165 180 240 200 165 27 in/min N/A 107C
    KIC set points
    (Paste Specs)
    94 129 154 193 234 166 133 24 in/min 93%

     

    Sn-Pb Product Zone #1 Zone #2 Zone #3 Zone #4 Zone #5 Zone #6 Zone #7 Conveyor Speed PWI Temperature set point difference
    Existing set points 120 140 165 180 240 200 165 27 in/min N/A 21C
    KIC set points
    (JEDEC Specs)
    120 139 161 170 237 187 175 24 in/min 53%

Company C:

  • Oven name: Vitronics Soltec XPM2
  • No of Zones: 8
  • No of products run: 1 Sn-Pb, 2 Pb-Free
    Pb-Free Product
    #1
    Zone #1 Zone #2 Zone #3 Zone #4 Zone #5 Zone #6 Zone #7 Zone #8 Conveyor Speed PWI Temperature set point difference
    Existing set points 110 120 160 180 200 240 270 275 25 in/min N/A 8C
    KIC set points 110 120 160 180 199 234 270 274 23 in/min 63%

     

    Pb-Free Product
    #2
    Zone #1 Zone #2 Zone #3 Zone #4 Zone #5 Zone #6 Zone #7 Zone #8 Conveyor Speed PWI Temperature set point difference
    Existing set points 135 145 155 185 220 245 285 275 23 in/min N/A 45C
    KIC set points 97 124 151 183 222 247 286 290 22 in/min 72%

     

    Sn-Pb Product Zone #1 Zone #2 Zone #3 Zone #4 Zone #5 Zone #6 Zone #7 Zone #8 Conveyor Speed PWI Temperature set point difference
    Existing set points 90 130 180 180 180 220 240 220 28 in/min N/A 50C
    KIC set points 71 117 181 170 159 209 249 234 23 in/min 69%

Data Analysis

Company A:

The data analysis for the Sn-Pb product run is discussed below:

[Mean Power Consumption Comparison - Company A]
Figure 2: Mean Power Consumption Comparison - Company A

From Figure 2 it is evident that the KIC profile appears to be consuming less power than Company A's profile.  This is indicated by the means (11122 and 11412 Watt-Hour respectively) shown in the table within the graph, as well as the relative position of the peaks for the fitted normal distribution.  The standard deviation for Company A's profile (395.4 Watt-Hour) is greater than the KIC profile (318.1 Watt-Hour), indicating a much tighter power consumption profile for KIC recommended setpoints, when compared to Company A's setpoints.

[Boxplot for Power Consumption in Company A]
Figure 3: Boxplot for Power Consumption in Company A

The box plot (Figure 3) reveals that the median power consumption for KIC recommended profile was lower than Company A's profile and the power consumption distribution for KIC recommended profile was considerably tighter than that for Company A's profile.  Even though graphically there seems to be a difference in the power consumption, KIC recommended profile providing lesser power consumption than the Company A's profile, it was necessary to determine if the difference observed was statistically significant.  This was carried out using the 2-Sample t-Test.

The 2-Sample t-Test is a hypothesis test for two population means to determine whether they are significantly different.  This procedure uses the null hypothesis that the difference between two population means is equal to a hypothesized value (H0: µ1‑µ2 = 0), and tests it against an alternative hypothesis, which can be left-tailed (µ1‑µ2 < 0) or right-tailed (µ1‑µ2 > 0).  If the t-Test's p-value is less than the chosen significance level (α=0.05), the null hypothesis will be rejected.

Two-Sample T-Test and CI: Power Consumption, Profile

Profile N Mean StDev SE Mean
KIC 121 11122 318 29
Company A 121 11412 395 36
Two-sample t-Test for Power Consumption
    Difference = µ (KIC) - µ (Company A)
    Estimate for difference: -290.9
    95% upper bound for difference: -214.7
    t-Test of difference = 0 (vs <): T-Value = -6.31; p-Value = 0.000; DF = 229

The results of the t-Test (p-value < 0.05) indicate that the difference between the average power consumption for the two profiles is significant.  Furthermore, there is a reduction in power consumption of 2.55% (290.9 Watt-Hour) with the KIC recommended profile.

Company B:

Company B had been using JEDEC specifications instead of the paste specifications for the Sn-Pb product considered for the experiment.  JEDEC specifications are much wider than the paste specifications, thereby posing the challenge of shrinking the process window within tighter specifications without compromising on the quality of the output.  For a better analysis, the KIC Navigator option was used to generate profiles for both the JEDEC and the paste specifications.  The data analysis is discussed below:

[Mean Power Consumption Comparison - Company B]
Figure 4: Mean Power Consumption Comparison - Company B

Both KIC profiles (KIC JEDEC and KIC Paste Specs) appear to be consuming less power when compared to Company B's profile, with the KIC Paste Specs being the best.  This is indicated by the means (12725, 11216 and 13042 Watt-Hour), as well as the relative position of the peaks for the fitted normal distribution.

The standard deviation for Company B's profile (2052 Watt-Hour) is slightly less than the KIC JEDEC profile, but greater than the KIC Paste Specs profile (1969 Watt-Hour).  This has resulted in a much steeper and tighter fitted distribution for KIC Paste Specs Profile.

[Boxplot for Power Consumption in Company B]
Figure 5: Boxplot for Power Consumption in Company B

The box plot comparing the profiles for Company B (Figure 5) shows that the median power consumption is higher for Company B's profile (13039.1 Watt-Hour) as compared to the KIC JEDEC (12999.1 Watt-Hour) and KIC Paste Specs (11165.7 Watt-Hour) profiles.

Comparison between Company B (JEDEC Specs) and KIC JEDEC Specs Profiles:

Two-Sample T-Test and CI: Power Consumption, Profile

Profile N Mean StDev SE Mean
KIC JEDEC Specs 121 12725 2064 188
Company B
(JEDEC Specs)
121 13042 2052 187
Two-sample t-Test for Power Consumption
    Difference = µ (KIC JEDEC Specs) - µ (Company B JEDEC Specs)
    Estimate for difference:  -317
    95% upper bound for difference:  120
    t-Test of difference = 0 (vs <): t-Value = -1.20; p-Value = 0.116; DF = 239

The results of the t-Test (p-value > 0.05) indicate that the difference between the average power consumption for the two profiles is not significant.  However, there is a reduction in power consumption of 2.43% (317 Watt-Hour) with the KIC recommended profile.  When using the JEDEC specifications the profile difference was not statistically significant.

Comparison between Company B (JEDEC Specs) and KIC Paste Specs Profiles:

Two-Sample T-Test and CI: Power Consumption, Profile

Profile N Mean StDev SE Mean
KIC JEDEC Specs 121 12725 2064 188
Company B
(JEDEC Specs)
121 13042 2052 187
Two-sample t-Test for Power Consumption
    Difference = µ (KIC Paste Specs) - µ (Company B JEDEC Specs)
    Estimate for difference:  -1826
    95% upper bound for difference:  -1399
    t-Test of difference = 0 (vs <): t-Value = -7.06; p-Value = 0.000; DF = 239

The results of the t-Test (p-value < 0.05) indicate that the difference between the average power consumption for the two profiles is significant.  Furthermore, there is a reduction in power consumption of 14% (1826 Watt-Hour) with the KIC recommended profile.

Company C: Product #1 (Pb-Free)

The data analysis for the first Pb-Free product run is discussed below:

[Mean Power Consumption Comparison - Company C Pb-Free Product 1]
Figure 6: Mean Power Consumption Comparison - Company C Pb-Free Product 1

The KIC profile appears to be a slightly lesser power consuming than the Company C's profile.  This is indicated by the tabled means (10800 and 11061 Watt-Hour, respectively), as well as the relative position of the peaks for the fitted normal distribution.  The standard deviation for Company C's profile (1178 Watt-Hour) is greater than the KIC profile (1065 Watt-Hour).  This has resulted in a shorter and wider-looking fitted distribution for company C's profile.

[Boxplot for Power Consumption in Company C for Pb Free Product 1]
Figure 7: Boxplot for Power Consumption in Company C for Pb Free Product 1

The box plot shown in Figure 7 reveals higher power consumption for Company C's profile (11328.5 Watt-Hour) as compared to KIC profile (10766.4 Watt-Hour).

Two-Sample T-Test and CI: Power Consumption, Profile

Profile N Mean StDev SE Mean
KIC 121 10800 1065 97
Company C
(Product #1)
121 11061 1178 107
Two-sample t-Test for Power Consumption
    Difference = µ (KIC) - µ (Company C Product #1)
    Estimate for difference:  -261
    95% upper bound for difference:  -22
    t-Test of difference = 0 (vs <): t-Value = -1.81; p-Value = 0.036; DF = 237

The results of the t-Test (p-value < 0.05) indicate that the difference between the average power consumption for the two profiles is significant.  There is a reduction in power consumption of 2.36% (261 Watt-Hour) with the KIC recommended profile.

Company C: Product #2 (Pb-Free)

The data analysis for the second Pb-Free product run is discussed below:

[Mean Power Consumption Comparison - Company C Pb Free Product 2]
Figure 8: Mean Power Consumption Comparison - Company C Pb Free Product 2

The KIC profile appears to be a slightly lesser power consuming than the Company C's profile.  This is indicated by the means in the table (11192 and 11237 Watt-Hour, respectively), as well as the relative position of the peaks for the fitted normal distribution.  However, the standard deviation for Company C's profile (984.2 Watt-Hour) is slightly lessthan the KIC profile (1151 Watt-Hour).  This has resulted in a shorter and wider-looking fitted distribution for KIC profile.

[Boxplot for Power Consumption in Company C Pb Free Product 2]
Figure 9: Boxplot for Power Consumption in Company C Pb Free Product 2

Median power consumption in both the profiles (Figure 9) is almost the same suggesting not much difference in the power consumption between the two profiles.

Two-Sample T-Test and CI: Power Consumption, Profile

Profile N Mean StDev SE Mean
KIC 121 11192 1151 105
Company C
(Product #2)
121 11237 984 89
Two-sample t-Test for Power Consumption
    Difference = µ (KIC) - µ (Company C Product #2)
    Estimate for difference:  -45
    95% upper bound for difference:  182
    t-Test of difference = 0 (vs <): t-Value = -0.33; p-Value = 0.372; DF = 234

The results of the t-Test (p-value > 0.05) indicate that the difference between the average power consumption for the two profiles is not significant.  There is minimal reduction in power consumption (45 Watt-Hour) with the KIC recommended profile.

Company C: Product #3 (Sn-Pb)

The data analysis for a Sn-Pb product run is discussed below:

[Mean Power Consumption Comparison - Company C Sn-Pb Product]
Figure 10: Mean Power Consumption Comparison - Company C Sn-Pb Product

The KIC profile appears to be a lesser power consuming profile than the Company C's profile.  This is indicated by the tabled means (9037 and 9250 Watt-Hour, respectively), as well as the relative position of the peaks for the fitted normal distribution.  The standard deviation for Company C's profile (1966 Watt-Hour) is greater than the KIC profile (1544 Watt-Hour).  This has resulted in a shorter and wider-looking fitted distribution for company C's profile.

[Boxplot for Power Consumption in Company C Sn-Pb Product]
Figure 11: Boxplot for Power Consumption in Company C Sn-Pb Product

Median power consumption is higher for Company C's profile (9731.28 Watt-Hour) as compared to KIC profile (8739.35 Watt-Hour)

Two-Sample T-Test and CI: Power Consumption, Profile

Profile N Mean StDev SE Mean
KIC 121 9037 1544 140
Company C
(Product #3)
121 9250 1966 179
Two-sample t-Test for Power Consumption
    Difference = µ (KIC) - µ (Company C Product #3)
    Estimate for difference:  -213
    95% upper bound for difference:  162
    t-Test of difference = 0 (vs <): t-Value = -0.94; p-Value = 0.175; DF = 227

The results of the t-Test (p-value > 0.05) indicate that the difference between the average power consumption for the two profiles is not significant.  However, there is a reduction in power consumption of 2.3% (213 Watt-Hour) with the KIC recommended profile.

Comparison between the Average Power Consumption for different companies

[Comparison of Mean Power Consumption for All Profiles]
Figure 12: Comparison of Mean Power Consumption for All Profiles

In all cases, the KIC recommended profiles have lower power consumption than the existing company profiles.

Comparison between the Std Dev of the Power Consumption for different companies

[Comparison of Std. Dev. of Power Consumption for All Profiles]
Figure 13: Comparison of Std. Dev. of Power Consumption for All Profiles

Moreover, the Standard Deviation of Power Consumption for all KIC Profiles is lesser than the existing company profiles.

Issues faced during Experimentation

Company A

  • The oven could not stabilize at the set points recommended by KIC Navigator due to its limitations (interference of the adjacent zone).  Due to this limitation, the minimum set point for the first zone had to be restricted to 110°C, even though the KIC software recommended 71°C.
  • For this site, one of the recent updates for the Beta version of the software was not available as KIC sent it later.

Company C

  • The software experienced a bug that predicted the same set points as the original.

Conclusions

  • The recipes recommended by the new KIC Navigator feature have been observed to have either reduced the power consumption when compared existing recipe or maintained it the same.  This is shown in the figure below (Figure 14):

    [Power Consumption Reduction for all Profiles]
    Figure 14: Power Consumption Reduction for all Profiles

     

  • Furthermore, it is also observed that in most cases, the percentage reduction in power consumption is 2% or higher, as shown in the figure below (Figure 15):

    [Percentage Reduction in Power Consumption]
    Figure 15: Percentage Reduction in Power Consumption

     

  • The new Navigator Power option has the capability to generate a reduced power consumption recipe without compromising the productivity and the quality of the output.

     

  • The software provides the flexibility to incorporate the restrictions offered by the reflow oven

     

  • The updated software version has a large solder paste menu (both Sn-Pb and Pb-Free) to select from.  This feature automatically feeds the solder paste specifications.